Citation: Ki-Hun Kim, Sang-Hoon Seol, Jino Park, Yeo-Jeong Song, Seunghwan Kim, Dong-Kie Kim. Induced atrial fibrillation during defibrillation test on implantation of subcutaneous implantable cardioverter defibrillator. J Geriatr Cardiol 2020; 17(8): 525-527. doi: 10.11909/j.issn.1671-5411.2020.08.007

Induced atrial fibrillation during defibrillation test on implantation of subcutaneous implantable cardioverter defibrillator

doi: 10.11909/j.issn.1671-5411.2020.08.007
More Information
  • loading
  • [1]
    Kamp NJ, Al-Khatib SM. The subcutaneous implantable cardi overter-defibrillator in review. Am Heart J 2019; 217: 131-139. doi: 10.1016/j.ahj.2019.08.010
    [2]
    Al-Ghamdi B. Subcutaneous implantable cardioverter defi brillators: an overview of implantation techniques and clinical outcomes. Curr Cardiol Rev 2019; 15: 38-48.
    [3]
    le Polain de Waroux JB, Ploux S, Mondoly P, et al. Defi brillation testing is mandatory in patients with subcutaneous im plantable cardioverter-defibrillator to confirm appropriate ven tricular fibrillation detection. Heart Rhythm 2018; 15: 642-650. doi: 10.1016/j.hrthm.2018.02.013
    [4]
    Boersma LV, EI-Chami MF, Bongiorni MG, et al. Under standing outcomes with the EMBLEM S-ICD in primary pre vention patients with low EF study (UNTOUCHED): clinical characteristics and perioperative results. Heart Rhythm 2019; 16: 1636-1644. doi: 10.1016/j.hrthm.2019.04.048
    [5]
    Chue CD, Kwok CS, Wong CW, et al. Efficacy and safety of the subcutaneous implantable cardioverter defibrillator: a systematic review. Heart 2017; 103: 1315-1322. doi: 10.1136/heartjnl-2016-310852
    [6]
    Wilkoff BL, Fauchier L, Stiles MK, et al. 2015 HRS/EHRA/ APHRS/SOLAECE expert consensus statement on optimal im plantable cardioverter-defibrillator programming and test ing. Heart Rhythm 2016; 13: e50-e86. doi: 10.1016/j.hrthm.2015.11.018
    [7]
    Pinski SL, Fahy GJ. The proarrhythmic potential of implant able cardioverter-defibrillators. Circulation 1995; 92: 1651-1664. doi: 10.1161/01.CIR.92.6.1651
    [8]
    Brembilla-Perrot B, Beurrier D, Houriez P, et al. Significance of external cardioversion induced atrial tachyarrhythmias. Pacing Clin Electrophysiol 2003; 26: 2111-2115. doi: 10.1046/j.1460-9592.2003.00328.x
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Figures(3)

    Article Metrics

    Article views (236) PDF downloads(7) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return